cable 10

          A                                          220 Shamrock St.         

          N                                          PINCOURT, QUEBEC,

                G                                         CANADA. J7V 3W4

          R                                         PH.  (514) 453-3848

          O                                        FAX  514-425-2404

          V                                e mail=info@rppdist.com

S A L E S     

 

HELUKABEL JZ-600 Number Coded, Flexible 0,6/1 kV   

 

Technical data

-   Special PVC control cables

-   Adapted to DIN VDE 0262/12.95 and
DIN VDE 0281 part 13, with insulation
thickness for 1 kV type

-   Temperature range

Flexing                         - 5°C to +80° C

Fixed installation         -40°C to +80°C

-   Nominal voltage   U0/U 0,6/1 kv

-   Test voltage 4000 V

-   insulation resistance
min. 20 MOhm x km

-   Power rating

as per DIN VDE 0298

-  Minimum bending radius

for permanent approx. 7,5xcable Æ

-  Radiation resistance

up to 80x106 cJ/kg (up to 80 Mrad)

-  Resistant to ultra violet rays

-The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers

Cable structure

-  Bare copper, fine wire conductors,
as per DIN VDE 0295 cl. 5 and

IEC 60228 Cl. 5

-    Special PVC core insulation TI2, to
DIN VDE 0281 part 1

-    Black cores with white figure imprints

to DIN VDE 0293

-    Green-yellow earth core in the outer
layer (3 cores and above)

-    Cores stranded in layers with optimal
lay-length

-    Separating foi l

-    Special PVC outer sheath TM2, to
DIN VDE 0281 part 1

color black

-    Extensively oil resistant
Chemical Resistance - see
table Technical Information

-    PVC self-extinguishing and flame retar dant test method B according to

VDE 0472 part 804 and IEC 60332-1

Application

Wiring cable for measuring and control­ ling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installa­tion). Is not suitable to be used as direct burial- or as underwater cable, The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resis­ tant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.

CE = The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.

Part

No.

No. cores x

cross-sec

mm2

Outer Æ

ca. mm

Cop.

weight

kg /km

Weight

ca. kg /km

AWG-

no.*)

1055 OZ 2x0,5 6,4 9,6 56 20
10551 3G0,5 6,8 14,4 68 20
10552 OZ 3x0,5 6,8 14,4 68 20
10553 4G0.5 7,6 19,0 100 20
10554 OZ 4x0,5 7,6 19,0 100 20
10555 5G0,5 8,2 24,0 117 20
10556 OZ 5x0,5 8,2 24,0 117 20
10557 6G0,5 9,1 29;0 126 20
10558 7G0,5 9,8 33,6 138 20
10559 OZ 7x0,5 9,8 53,6 138 20
10560* 8G0,5 10,7 58,0 150 20
10561 OZ 8x0,5 10,7 38,0 150 20
10562 10G0,5 11,6 48,0 176 20
10565 12G0,5 12,2 53,0 200 20
10564 OZ 12x0,5 12,2 58,0 200 20
10565 14G0,5 12,8 67,0 230 20
10566 16G0,5 13,7 76,0 250 20
10567 18GO,5 14,4 86,0 276 20
10568 20G0,5 15,3 96,0 293 20
10569 21G0,5 16,0 96,0 305 20
10570 25G0,5 17,2 120,0 355 20
10571 30G0,5 18,0 144,0 348 20
10572 32G0,5 18,9 154,0 355 20
10575 34G0,5 19,8 163,0 520 20
10574 40G0,5 21,2 192,0 590 20
10575 42G0,5 21,2 202,0 595 20
10576 50G0,5 23,4 240,0 715 20
10577 52G0,5 24,3 252,0 740 20
10578 61G0,5 26,0 295,0 840 20
10579 65G0,5 26$ 312,0 880 20
10580 80G0,5 28,9 584,0 960 20
10581 100G0,5 33,5 480,0 1050 20
           
           

Part

No.

No. cores x

cross-sec

mm2

Outer Æ

ca. mm

Cop.

weight

kg /km

Weight

ca. kg /km

AWG-

no.*)

10582 OZ 2x0,75 6,8 14,4 66 18
10585* 3G0,75 7,2 21,6 74 18
10584 OZ 3x0,75 7,2 21,6 74 18
10585* 4G0,75 8,0 29,0 126 18
10586 OZ 4x0,75 8,0 29,0 126 18
10587 5G0,75 8,8 36,0 140 18
10588 OZ 5x0,75 8,8 56,0 140 18
10589 6G0,75 9,7 43,0 170 18
10590 OZ 6x0,75 9,7 43,0 170 18
10591 7G0,75 10,7 50,0 190 18
10592 OZ 7x0,75 10,7 50,0 190 18
10595 8G0,75 11,5 58,0 212 18
10594 OZ 8x0,75 11,5 58,0 212 18
10595 9G0,75 12,5 65,0 227 18
10596 10G0,75 12,7 72,0 238 18
10597* 12G0,75 13,1 86,0 257 18
10598 OZ 12x0,75 13,1 86,0 257 18
10599 14G0,75 13,9 101,0 286 18
10600 15G0,75 14,7 108,0 319 18
10601 18G0,75 15,6 130,0 362 18
10602 20G0,75 16,6 144,0 594 18
10603 21G0,75 17,3 151,0 422 18
10604 25G0,75 18,9 180,0 486 18
10605 32G0,75 20,5 230,0 595 18
10606 54G0,75 21,5 245,0 638 18
10607 37G0,75 21,5 260,0 696 18
10608 40G0,75 25,2 288,0 726 18
10609 41G0,75 23,2 296,0 750 18
10610 42G0,75 23,2 302,0 770 18
10611 50G0,75 25,6 360,0 895 18
10612 61G0,75 28,2 439,0 1070 18
10613 65G0,75 29,0 468,0 1110 18
10614 80G0,75 51,4 576,0 1500 18
10615 100G0,75 36,2 720,0 1889 18

* These dimensions are also available with red resp. blue cores.  

  G = with green-yellow earth core  

  X = without green-yellow earth core (OZ)  

PVC cables will be changed to lead free PVC successively.

*) Note

    AWG sizes are approximate equivalent values. The actual

    cross-section is in mm2