HELUKABEL JZ-600-Y-CY EMC*-preferred type         

0,6/1 kV, Flexible, numbered, Cu Shielded

Technical data

- Special control cables with thermo-

plastic PVC insulation

- On the basis of DIN VDE 0262/12.95 and

DIN VDE 0281 part13

- Temperature range

Flexing                       - 5°C to +80°C

Fixed installation       -40° C to +90° C

- Nominal voltage U0/U 0,6/1 kV

- Test voltage 4000 V

- Insulation resistance

min. 20 MOhm x km

- Power rating according to

DIN VDE 0298

- Minimum bending radius

for permanent, approx. 10 x cable Æ

- Radiation resistance

up to 80x106 cJ/kg (up to 80 Mrad)

- Resistant to ultra violet rays

- Coupling resistance

max. 250 Ohm/km

- The materials used in manufacture are

cadmium-free and contain no silicone

and free from substances harmful to the wetting properties of lacquers

 

Cable structure

- Bare copper, fine wire conductors,

  according to DIN VDE 0295 cl. 5 and

  IEC 60228 c I.5

- Special PVC core insulation TI2, to

  DIN VDE 0281 part 1

- Black cores with sequential numbering

  imprinted in white, according to

  DIN VDE 0293

- Green-yellow earth core in the outer

  layer (3 cores and above)

- Cores stranded in layers with optimal lay-length

- PVC-insulated inner sheath

- Braided screen of tinned Cu wires, coverage 

  approx, 85%

- Special PVC outer sheath TM2, to

  DIN VDE 0281 part 1 color black

- Extensively oil resistant & Chemical Resistance 

- PVC self-extinguishing and flame retar dant, test

  method B according to VDE 0472 part 804 and

  IEC 60332-1

Application

Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills.   Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and we rooms as well as outside (fixed installa tion). Is not suitable to be used as direct burial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resis tant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. Interference-free trans mission of signals and pulses is assured by the high degree of screening.

 

* EMC = Electromagnetic compatibility

Note To optimize the EMC features we

recommend a large round contact of the

copper braiding on both ends.

C€ = The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.

Part

No.

No. cores x

cross-sec

mm2

Outer Æ

ca. mm

Cop.

weight

kg /km

Weight

ca. kg/km

AWG-

no.*)

11464 OZ 2x0,5 8,3 25,9 129 20
11465 3G0,5 8,6 38,9 150 20
11466 4G0.5 9,4 51,3 170 20
11467 5G0,5 10,1 64,9 199 20
11469 7G0,5 12,1 94,1 235 20
11472 12G0,5 14,7 168,2 320 20
11475 18G0,5 17,3 266,5 428 20
11478 25G0,5 20,6 372,0 503 20
           
11489 OZ 2x0,75 8,7 39,0 143 18
11490 3G0,75 9,0 58,3 155 18
11491 4G0,75 9,9 78,3 190 18
11492 5G0,75 10,8 97 2 228 18
11494 7G0,75 13,0 135,0 323 18
11498 12G0,75 15,8 249,0 410 18
11501 18G0,75 17,9 357,0 560 18
11504 25G0,75 22,8 458,0 730 18
            
11516 OZ 2x1 9,4 51,8 150 17
11517 3G1 9,8 78,3 163 17
11518 4G1 10,8 103,7 200 17
11519 5G1 12,1 129,6 239 17
11521 7G1 14,5 187,6 289 17

Part

No.

No. cores x

cross-sec

mm2

Outer Æ

ca. mm

Cop.

weight

kg /km

Weight

ca. kg/km

AWG-

no.*)

11528 18G1 20,7 501,7 628 17
11532 25G1 24,8 644,0 855 17
11525 12G1 17,4 333,5 464 17
            
11546 OZ 2x1,5 10,2 78,3 162 16
11547 3G1,5 10,9 116,1 187 16
11548 4G1,5 12,2 156,6 240 16
11549 5G1,5 13,3 194,4 289 16
11551 7G1,5 16,0 282,8 383 16
11556 12G1,5 19,6 501,7 592 16
11559 18G1,5 23,4 751,1 806 16
11563 25G1,5 28,2 1016,0 1241 16
            
11574 OZ 2x2,5 11,5 129,6 272 14
11575 3G2,5 12,2 194,4 298 14
11576 4G2,5 13,4 259,2 345 14
11577 5G2,5 14,9 324,0 427 14
11578 7G2,5 17,9 470,4 561 14
11580 12G2,5 21,9 777,6 857 14
11582 18G2,5 26,1 1152,8 1355 14
11584 25G2,5 31,9 1760,0 1995 14
           
           

G = with green-yellow earth core  

X = without green-yellow earth core (OZ)  

PVC cables will be changed to lead free PVC successively.

*) Note

    AWG sizes are approximate equivalent values. The actual

    cross-section is in mm2