IMPORTANT: The Multi Hole fittings
will meet NEMA 4x = IP68 if the design parameters are
complied with. To verify a submersible NEMA 6 = IP68
application, the final assembly of cables and fitting
must be tested by the customer or submitted at the
customer's expense to an independent test lab or
for certification.
DESIGN PARAMETERS: Cable diameter should not be less
than 80% of hole diameter and the difference between
hole and cable diameter should never exceed .04" (1 mm).
SPECIAL INSERTS: For a minimum of 1,000 pieces any
special insert hole or profile configurationis
available. For small quantities we suggest drilling or
machining the frozen solid plug insert, using the
fitting as a fixture.